Frete Grátis em todo o BrasilProduto Original Importado dos EUA

Dual SPST-NO 10 Amp Power Relay Module (AC/DC 5V)

*$327.40

(37 avaliações de clientes)
Add to Cart
Dual SPST-NO 10 Amp Power Relay Module (AC/DC 5V)
Dual SPST-NO 10 Amp Power Relay Module (AC/DC 5V)
*$327.40
SKU: DA3E84F7 Categoria: Marca:
  • Dual SPST-NO 10 Amp Power Relay Module.
  • Input control support AC and DC signal. Control voltage 5V 12V 24V version selectable.
  • Relay switch contact capacity: AC 250V 10Amp / DC 30V 10Amp.
  • Two separate input and SPST-NO switch circuit, can flexible selection control signal, for separate AC, for separate DC, for source (PNP, common +) , for sink (NPN, common -).
  • Compact ABS plastic case and wires connect for easy mount. Two screw mounting holes are convenient for you to fix it on the wall or wooden board. Of course, you can also choose not to lock the screw.

Informação adicional

Connector Type

Screw

Contact Type

Spst

Current Rating

10 Amps

Mounting Type

Screw Mount

Brand

HCDC

37 avaliações para Dual SPST-NO 10 Amp Power Relay Module (AC/DC 5V)

  1. Marker

    I received it and sent it back. No longer needed.

  2. John S

    Used as a relay to automate my garage doors. Worked perfectly with 24vac input for 6 months. But last night my doors were opening and closing on their own. I took a peak in the garage and the relay had the distinctive buzz that failed relays have.

    My advice, go with a better relay of reliability is of concern. I have a few from OONO as well as these (link below). I have had four running for years without issue. I am upgrading my use case to these as I type. 4X the cost, but hopefully 10x the reliability.

    Functional Devices RIB2401B… https://www.amazon.com/dp/B000LEUJU6?ref=ppx_pop_mob_ap_share

  3. W. Lancto

    Compact and easy to wire, just wish they had a single SPST-NO as I only needed one relay. Used to control an old milivolt wall furnace with a modern 24v smart thermostat.

  4. Jennings Sturgeon

    None

  5. Jeffrey S.

    I used this to activate booster fans in my HVAC system. I set one input up for heat, and one for cool so that whenever my system was active so we’re my boosters. This relay was just to send a signal to my 110v relay that actually powered the fans. It worked exactly as I intended it to work. My upstairs stays heated and cooled as it should without me messing with signal wires.